Wireless PTLevel Calibration Procedure

Wireless PTLevel Calibration Procedure

You are here:
Estimated reading time: 1 min

After you’ve installed your new device and setup the depth of your tank, you must calibrate the device in order to achieve a proper reading. This process is simple and is explained below.

You can not calibrate at 0% or really low levels, and you must not calibrate when your device is not fully functional yet.

Calibration Procedure

To top

First press the “Connect” button on the transmitter. This obtains the latest level reading online before calibrating.

Connect Button

Measure the amount of liquid in the tank. Then divide that measurement by the full empty depth of the tank.

Example: 72″ of water / 144″ tank height = 0.5

Multiply the above result with 100 to get the current percentage.

Example: 0.5 * 100 = 50%

Enter the result into the calibration input online once. Then hit the green save icon beside the form. You can find this form under your device “Features” button on the dashboard.

Calibration

Finally, press the “Connect” button on the transmitter one more time for it to calibrate to the most recent reading.

If you have to calibrate often, you may have a different issue. Please see the other articles available to you for further troubleshooting. It is also acceptable for the reading to be off a few percent over the full range. This is due to environmental changes and the tolerances of the sensor.

 